For Sales / Support Call / Email:

+91 20 26930908 / 26930960 / 61 Sales@steamequipments.com

TEK-FLUX 1400A

Electromagnetic Flowmeter

ECO-FLASH, flash vessels are used for separation of flash steam from high pressure condensate thereby generating useful low pressure steam totally free of cost. ECO-FLASH is supplied with all standard accessories like safety valve, pressure gauge, Valve, double window sight glass, steam trap and strainer.

  • Wide range of nominal diameter Size ½” to 28” (15 mm to 700 mm) with IP68 protection
  • Easy maintenance due to no moving parts
  • Uninfluenced by temperature, pressure, viscosity, and density
  • Used for wide application, can measure conductive fluid, without reference to fibre, solid or suspending material contained in liquid
  • High turndown ratio up to 1:100
  • It features high intelligence, with back light LCD display, menu setting control, three grades password protection, two-way measuring, slight signal removal, auto flow compensation, and other function.
  • Features high intelligence, which ensure empty pipe detection, self-detection, self-diagnostic functions, and safety alarms for upper and lower limit
  • Features SMART excitation, which ensures zero-point stability, high reliability, and low power consumption
  • Lining and electrode available in various materials which can measure nearly all conductive fluids
  • It has multiple signal output, pulse, Modbus RS485 or HART® or 4 to 20 mA

Service

Compatible conductive liquids

Measuring Range

flow range please refer the catalog 

Lining Materials

PTFE and Synthetic rubber

Electrode Material

Stainless Steel, Hastealloy C

Accuracy

±0.5%

Repeatability

0.15%

Ambient Temperature Limits

sensor (Remote Mount): -4 °F to 158 °F (-20 °C to 70 °C)

Converter: -4 °F to 122 °F (-20 °C to 50 °C)

Integral Type: 14 °F to 122 °F (-10 °C to 50 °C)

Ambient Magnetic Field

≤ 400 A/m

Pressure Limit

≤ 150 PSI

Mounting Orientation

Horizontal or vertical

Process Connection

#150 ANSI or AWWA flanges

Output Signal

Pulse and 4 to 20 mA or Modbus RS485 or 4 to 20 mA with HART

Power Requirements

18 VDC to 28 VDC or 85 VAC to 220 VAC

Conductivity

≥5 μs/cM

Enclosure Rating

IP68

Agency Approvals

CE

  • It can measure highly corrosive medium such as concentrated acid and concentrated alkaline using PTFE lining material.
  • By using Hastelloy C electrode we can measure seawater and brine application Trace humidity in oxygen purity.
  • Wide range of nominal diameter Size ½” to 28” (15 mm to 700 mm) with IP68 protection
  • Easy maintenance due to no moving parts
  • Uninfluenced by temperature, pressure, viscosity, and density
  • Used for wide application, can measure conductive fluid, without reference to fibre, solid or suspending material contained in liquid
  • High turndown ratio up to 1:100
  • It features high intelligence, with back light LCD display, menu setting control, three grades password protection, two-way measuring, slight signal removal, auto flow compensation, and other function.
  • Features high intelligence, which ensure empty pipe detection, self-detection, self-diagnostic functions, and safety alarms for upper and lower limit
  • Features SMART excitation, which ensures zero-point stability, high reliability, and low power consumption
  • Lining and electrode available in various materials which can measure nearly all conductive fluids
  • It has multiple signal output, pulse, Modbus RS485 or HART® or 4 to 20 mA