For Sales / Support Call / Email:
+91 20 26930908 / 26930960 / 61 Sales@steamequipments.com
Sampling System Solutions
Analytical Division
pH Analyzer
Conductivity Analyzers
Dissolved Oxygen Analyzer
Chlorine Analyzers
TOC Analyzer
Silica Analyzer
Iron Analyzer
Oil in Water Analyzers
Hydrazine Analyzer
Hardness Analyzer
Chloride Analyzer
Phosphate Analyzer (Yellow Method)
Phosphate Analyzer (Blue Method)
Dissolved Zinc Analyzer
Sulphate Analyzer
Aluminum Analyzer
Cyanide Analyzer
Manganese Analyzer
Nitrite Analyzer
Sodium Analyzer
Alkalinity Analyzer
Ion Selective Analyzer
Sulfide Analyzer
COD-BOD-TSS Analyzers
Turbidity Analyzer
Optical DO Analyzer
Sequencer
Environmental Solutions
Steam Engineering
Oxygen Transmitter
Design
This model utilizes a design to meet the requirements of NEMA-4(IP-66) levels as well as ATEX Zone 0/1/2 and FM/FMc Class I Div 1 approvals when used with select intrinsic safety barriers. In addition, the CSA approval extends to Class I Div 2 as a non-incentive device without the use of barriers. The transmitter head contains the electronics and user display interface including 4-button design to access functions.
Platform
A fully upgraded microprocessor-based platform gives a more compact, single PCB design to simplify maintenance and reduce shelf spares. The new interface allows for a fully settable single range form 0-10 ppm to 0-25%. New advanced functions are also available as standard including 4-20mA output adjustment to optimize single output and cold boot capability as a beneficial troubleshooting tool.
Additional Advantages
• 2-wire transmitter form factor
• InstaTrace capability for fast recovery from new sensor installation (optional) Accepts most industrial micro-fuel cells
• Trace or percent oxygen analysis – settable ranging from 0-10 ppm to 0-25%
• Intrinsically safe design for hazardous are non-hazardous installations
Fittings (all 316SS)
• Standard – 1/8″ tube
• 1/4″ tube
• 6mm tube
• No fitting – 1/8″ FNPT thread
InstaTrace for Fast Initial Recovery
• Non InstaTrace
• InstaTrace
O-ring Seals
• Standard Viton®
• Buna-n
• Kalrez®
• EPDM
• EPR
• Neoprene
• Chemraz®
• Single user-settable range, 0-10 ppm to 0-25% Oxygen
• Front-facing head containing digital display and keys for convenient wall mounting
• Accepts most Teledyne industrial sensors (InstaTrace and A-5 type cells require special configurations)
• Weather-tight housing designed to meet NEMA-4 / IP-66 ingress protection requirements
• 316SS cell housing with 316SS 1/8″ tube fittings and Viton® O-ring as standard
• Optional fittings: 1/4″ tube, 6mm tube, no fitting (1/8″ FNPT threads)
• Optional O-rings of Kalrez®, EPDM, EPR, Neoprene, Chemraz® and Buna-n
• Microprocessor-based single PCB design
• 4.5 digit LCD
• 4-20mA loop output
• Cold boot and 4-20 fine adjust features included as standard
• Intrinsically safe to ATEX Ex ia IIC T4 Ga when wired with approved barrier as per D86181 Interconnection Diagram
• Intrinsically safe to FM / FMc Class I Div 1 Gp A-D T4 when wired with approved barrier as per Interconnection Diagram and FM / FMc Class I Div 2 Gp A-D T4 without barrier (approvals pending)
• Cable included, 2-conductor 22 AWG shielded, 24 inch (610 mm) length
• Fuel cell included
Range | Single-range, user-settable, 0-10 ppm to 0-25% |
Micro-Fuel Cells | Trace O2 general service: Class B-2C |
Temperature | 32° to 122°F (0° to 50°C) |
Accuracy | ± 1% of FS operating range |
Response Time | 15 seconds |
Flow Rate | 1-2 SCFH (0.5-1 SLPM) |
Display | 4.5 digit LCD |
Power | 9-24 VDC, loop-powered |
Output | Loop 4-20 mADC |
Weight | Approximately 6 lbs |
• Air separation and liquefaction
• Pure, gaseous hydrocarbon stream monitoring
• Emissions monitoring
• Protective atmosphere blanketing of primary liquid feedstocks and flammable liquids
• Process monitoring of gaseous monomers – vinyl chloride, propylene, butadiene, isoprene, or ethylene
• Gas purity certification
© 2020. Steam Equipments Pvt Ltd. All Rights Reserved.