For Sales / Support Call / Email:
+91 20 26930908 / 26930960 / 61 Sales@steamequipments.com
Sampling System Solutions
Analytical Division
pH Analyzer
Conductivity Analyzers
Dissolved Oxygen Analyzer
Chlorine Analyzers
TOC Analyzer
Silica Analyzer
Iron Analyzer
Oil in Water Analyzers
Hydrazine Analyzer
Hardness Analyzer
Chloride Analyzer
Phosphate Analyzer (Yellow Method)
Phosphate Analyzer (Blue Method)
Dissolved Zinc Analyzer
Sulphate Analyzer
Aluminum Analyzer
Cyanide Analyzer
Manganese Analyzer
Nitrite Analyzer
Sodium Analyzer
Alkalinity Analyzer
Ion Selective Analyzer
Sulfide Analyzer
COD-BOD-TSS Analyzers
Turbidity Analyzer
Optical DO Analyzer
Sequencer
Environmental Solutions
Steam Engineering
Ultrafast Gas Chromatograph
The Teledyne Falcon UltraFast Gas Chromatograph is Faster, Smaller, Smarter, Easier and Greener.
Faster
With analytical cycles 10 to 50 times faster than traditional chromatographs, the Falcon Series Ultrafast Gas Chromatograph (GC) vastly increases responsiveness for the data consumer in a wide range of lab, process and field applications. Less time is spent waiting on results which means more productivity and timely control of measured processes. Product output, quality and profitability are increased while field analysis becomes more practical and reliable.
The Falcon Series GC’s incredible speed inspired a new Ultrafast Simulated Distillation Method. The ASTM D7798 method can perform simulated distillation nearly 6 times faster than the previous method (D2887), with superior repeatability and reproducibility.
Smaller
The elimination of the air bath column ovens, required for traditional gas chromatography, drastically reduces the Falcon Series GC footprint. Yet, the Falcon Series delivers all the functionality of much larger, higher thermal mass, traditional GCs. At 17” wide, 8.5” deep, 11” high and 25 Lbs. (43 cm x 22 cm x 28 cm & 11kg), the Falcon Series offers advanced analytical chemistry in a highly compact, versatile package.
The smaller size of the Falcon Series GC means more efficient utilization of space and, ultimately, bigger profits for the user. The small Falcon Series footprint allows for higher installation density in the laboratory and enables process installation schemes that place the analyzer much closer to its sampling point in the plant. Closer proximity means less sample lag time as well as more representative measurements for process control. This also makes hand carried and vehicular transport applications far more feasible.
Smarter
Using modern computing with standard operating systems and software, the Falcon Series GC frees valuable technical resources from the daily grind of interpreting and validating chromatographic results. State-of-the-art Chromperfect® GC operating software is built in and LineUp™ software virtually eliminates misidentification of components and drastically reduces the need for expensive calibration sample runs. Less time spent calibrating the analyzer means more time spent on more economically valuable diagnostics, most notably measured process deviations from the set-point. In addition to Chromperfect®, Infometrix Pirouette® is an optional software that may be added to enable interface with process automation.
Easier
Teledyne’s patented direct heating of the temperature-programmed column modules allow the Falcon Series GC to avoid the complicated and troublesome valve schemes used in isothermal process analyzers and many lab gas chromatographs. The Falcon Series GC’s patented overall modular design also makes diverse application engineering and maintenance easier, as column and detector modules are readily changed out as needed.
Correlation between laboratory systems and online process control systems become realistically possible with the Falcon Series system, because both physical packages use the same measurement principle, hardware and methodology. Applying the Falcon Series GC in-lab and online means less time spent reconciling lab and process measurements and validating which result is correct. More time can be spent working on valuable, direct process optimization.
Greener
The obvious and extraordinary features and benefits of the Falcon Series GC combine to yield something that may not be that evident: Green Process Analytical Chemistry. The Falcon Series GC is greener, whether in the control laboratory, online in the processing plant, near line in the pilot plant or when transported for field measurements. By consuming less than 300 Watts in operation, the Falcon Series GC uses about 1/10th of the power of traditional GCs.
With analytical cycles that are many times faster and the low electrical load needed for operation, the Falcon Series GC’s power consumption per analysis is 1% or less of the energy required by traditional gas chromatography. Combine these savings with the reduction in workload for air conditioning systems and the Falcon Series solution is greener still. The Falcon Series product life cycle environmental impact from manufacturing throughout its useful lifetime to disposal is far less than traditional GCs.
The Result
Faster, Smaller, Smarter, Easier, Greener = better quality, increased productivity, profitability and versatility, with far less hassle and environmental impact. That summarizes the business concept for the ultrafast, compact, ultra-user friendly, energy efficient, highly durable, practical, reliable and economical Falcon Series Ultrafast Gas Chromatograph.
Column Module and Detector Module
With its patented modular columns and detectors platform, application range is second only to analytical speed in the list of Falcon Series GC advantages. Consider these diverse capabilities:
Process Enclosure
The Falcon Series process enclosure is also modular and compact. The all-weather Falcon Series enclosure can even be tucked away “in the pipes” when needed. For most environments, the Falcon Series enclosure can be installed outdoors with only rain and sun protection, or in very economical 3-sided shelters. The enclosure module also includes an optional built in efficient air conditioning system and has configurations for NEC, ATEX or IECEx hazardous area locations available with purge.
Autosampler
The Falcon Series GC Autosamplers offer many outstanding features.
Servo motor drive
Simultaneous X-Y movement – not sequential
Faster, quieter – more reliable movement
Fast injections – software programmed control
Simple operation methods linked to the Falcon Series GC Ultra-reliable and durable
Direct syringe and heated headspace injections Headspace analysis
Variable injection rates
Variable syringe fill rates
Multiple tray options
Mobile System
The Falcon Series GC’s compact size and superior performance makes mobile systems for GC analysis a functional reality.
Upstream E&P evaluations
Environmental emissions monitoring
Roadside fuel marker detection
Transportable product authentication
Pipeline product interface detection
Forensic analysis
Fence-line monitoring
Additional Features
The Falcon Series Ultrafast Gas Chromatograph is a widely applicable, fast programmed temperature gas chromatograph consisting of:
Injection methods include gas or liquid manual syringe injections, liquid or heated headspace autosampler injections and gas or liquid sample valve injections
The sample can be drawn in through the inlet via a sample vacuum pump and is typically used in ambient air monitoring
One or two column modules can be run simultaneously either in a series or parallel to one or two detectors
Teledyne’s patented direct heating, precalibrated and individually programmed temperature column modules, enabling dual simultaneous analysis on the same sample, using different separation media and temperature profiles for maximum selectivity
Flame Ionization Detection, Thermal Conductivity Detection, Flame Photometric and Dielectric Barrier Discharge detectors are available
Maximum detector operating temperature is 662°F (350°C), application dependent
Chromperfect® chromatography data system running on a Windows PC. Optional Infometrix® and Pirouette® software may be added to enhance data analysis and interface
System configurations enabling measurements of fixed gases up through components with boiling points equivalent to n – C50. Samples can be gas or liquid phase and can be directly injected into the split/splitless injection port. Optional SP/ME and other sampling methods are available
See technical specifications for more information
Available Detectors
Flame Ionization (FID), Thermal Conductivity (TCD), Flame Photometric (FPD), Dielectric Barrier Discharge (DBD) (configured as helium ionization or electron capture)
Sampling Configurations
Process online via sample valve for gas or liquid*
Manual syringe injection for gas or liquid
Autosampler injections for liquid or heated headspace
Aspiration to inlet via sample pump
*Sample handling available
Detector / Column Configurations
101: Single column (2-16 meters), single detector
201: Dual column (4-32 meters), dual detector in series
301: Dual column (2-16 meters), dual detector in parallel
CS: Dual column (2-16 meters), dual detector with column switching valve
GS: Single column (2-16 meters) with large sample loop, single detector w/ sample pump
GS-T: Single column (2-16 meters) with preconcentration trap, single detector w/ sample pump
Repeatability
< ± 1% Relative Standard Deviation (RSD)
Temperature
Operating: 32° to 95°F (0° to 35°C)
Storage: -4° to 140°F (-20° to 60°C)
Utilities
Carrier Gas (application-dependent)
UHP hydrogen and zero air (99.999% pure) (for FID and FPD only)
Power
100-240 VAC 50/60 Hz with external converter
24 VDC power, 300 Watts max
Data Management
Front-panel touchscreen for GC initialization and manual sampling functions
RS-232 and all other functions via TCP/IP Ethernet to external PC with Chromperfect® Seven software (Windows® 10 or higher OS required)**
**Windows is a registered trademark of the Microsoft Corporation
Outputs***
Analog Outputs: 4-20 mADC (isolated), 0-1 VDC, 0-5 VDC
Digital Outputs: Relay contacts
TCP/IP MODBUS
Others available upon request
***Via external PC modules
Dimensions
17″W x 11″H x 8.5″W (43 x 22 x 28 cm)
Approximately 25 lbs (11 kg)
Boiling Range Distribution of Gasoline and Gasoline Fractions D3710
BTEX in Ambient Air
Catalyst Reaction Monitoring (chemical)
Catalyst Reaction Monitoring (Hydrocarbon Processing)
Ethanol in Wine and Distilled Spirits
Extended Natural Gas
Fermenter Off Gas
Food Grade Fatty Acids
Fusel Oils In Wine and Distilled Spirits
HC analysis of Upstream Condensate Samples
Liquefied Petroleum Gases
Marker Analysis in Fuel
Methyl Acetylene and Propadiene in Ethylene Process
Propylene Oligomers
Reactor Monitoring
Refinery Gas
SF6 Tracer
SIMDIS Analysis for Diesel in Lube Oil
SIMDIS Analysis for Gasoline Blending
SIMDIS Analysis for Liquid Fuels and Fuel Component Characterization
Simulated Distillation D7798
Sulfur Components in Liquid Phase HC Samples
Sulfur Compounds in C1-C6+ in Refinery Gas
Sulfur Compounds in Propylene
Sulfur in Coker Gas
Total Non-Methane HCs and Sulfur Compounds in Ambient Air
Total Non-Methane Hydrocarbons in Ambient Air
Total Petroleum Hydrocarbons
© 2020. Steam Equipments Pvt Ltd. All Rights Reserved.