For Sales / Support Call / Email:
+91 20 26930908 / 26930960 / 61 Sales@steamequipments.com
Sampling System Solutions
Analytical Division
pH Analyzer
Conductivity Analyzers
Dissolved Oxygen Analyzer
Chlorine Analyzers
TOC Analyzer
Silica Analyzer
Iron Analyzer
Oil in Water Analyzers
Hydrazine Analyzer
Hardness Analyzer
Chloride Analyzer
Phosphate Analyzer (Yellow Method)
Phosphate Analyzer (Blue Method)
Dissolved Zinc Analyzer
Sulphate Analyzer
Aluminum Analyzer
Cyanide Analyzer
Manganese Analyzer
Nitrite Analyzer
Sodium Analyzer
Alkalinity Analyzer
Ion Selective Analyzer
Sulfide Analyzer
COD-BOD-TSS Analyzers
Turbidity Analyzer
Optical DO Analyzer
Sequencer
Environmental Solutions
Steam Engineering
Gas Chromatograph
The 4000 Series GC leverages state-of-the-art Chromperfect® operating software to virtually eliminate misidentification and drastically reduces the need for expensive calibration sample runs. It also spends less time waiting on results which means more productivity and timely control of measured processes. The modular design of the 4000 Series GC allows for diverse application engineering and makes the maintenance easier, as column and detector modules are readily changed out as needed. Along with being faster, smarter and easier than traditional chromatographs, the 4000 Series comes with the following capabilities.
Chromperfect® Seven™
Chromperfect® Seven is a new PC based data system designed to meet the needs and budgets of smaller laboratories, offers much more than expensive competitive systems and shares the same core software as any other Chromperfect® system. It has a fully featured system with ease of use at the forefront of the product’s innovative design.
Available Detectors
Flame Ionization (FID), Thermal Conductivity (TCD), Flame Photometric (FPD), Dielectric Barrier Discharge (DBD) (configured as helium ionization)
Detector/Column Configurations
101: Single column (2-16 meters), single detector
201: Dual column (4-32 meters), dual detector in series
301: Dual column (2-16 meters), dual detector in parallel
CS: Dual column (2-16 meters), dual detector with column switching valve
GS: Single column (2-16 meters) with large sample loop, single detector w/ sample pump
GS-T: Single column (2-16 meters) with preconcentration trap, single detector w/ sample pump
Repeatability
< ±1% Relative Standard Deviation (RSD)
Temperature
Operating: 32° to 95°F (0° to 35°C)
Storage: -4° to 140°F (-20° to 60°C)
Utilities
Carrier Gas (application-dependent)
UHP hydrogen and zero air (99.999% pure) (for FID and FPD only)
Power
100-240 VAC 50/60 Hz
Data Management
Front-panel touchscreen for GC initialization and manual sampling functions
RS-232 and all other functions via TCP/IP Ethernet to external PC with Chromperfect® Seven software (Windows® 10 or higher OS required)**
**Windows is a registered trademark of the Microsoft Corporation
Outputs
Up to 6 x 4-20 mADC (isolated) outputs
MODBUS-TCP (optional)
Dimensions
8.7″H x 19.0″W x 22.3″D
(22.1 x 48.3 x 56.6 cm)