The Model 3010PB analyzer is a versatile, microprocessor-based instrument for detecting oxygen in a variety of gases. It serves as a general purpose unit.
Three Analysis Range
Three user-configurable ranges are standard, with excellent linearity precluding recalibration when changing ranges. Two fully programmable concentration alarms and relay functions provides the versatility to satisfy nearly any requirement. All features offer a sophistication that assure years of reliable service.
Convenient Outputs
Standard 0-1 VDC and isolated 4-20 mADC outputs are provided for oxygen measurements and range identification. An RS-232C serial port allows the user to introduce span and zero gases through a host computer.
Split Architecture
This unit is designed as a “split architecture” instrument. It is a general purpose, wall mounted control unit for non-hazardous areas and controls a remote analysis unit that can operate in hazardous areas. Simple menu choices, membrane command switches, and a large LED display make setup and operation clear and quick.
Maintenance-Free
The instruments use a long life Micro-fuel Cell to measure traces of O2 in the sample gas. The sensor sets industry standards for accuracy and sensitivity, and comes with a 1 year warranty. Expected life for the sensor is two years. The sensor is specific to oxygen and accurately monitors gas streams containing up to 100% hydrocarbons. The Micro-fuel Cell produces an output that is linear from 0 ppm to 100% O2 enabling the use of ambient air for calibration. These units can also accommodate the use of a certified ppm O2 span or zero gas which speed calibration when necessary.
Options
C Electrically operated cal/zero valves
V Vacuum service
S Stainless steel cell block
F Flame arrestors for Group C & D service
H Flame arrestors for Group B service
• Three user-programmable ranges (0-1% to 0-100%) plus cal range (0-25%)
• Five digit oxygen concentration LED display
• Signal output: 0-1 VDC and 4-20 mA Isolated
• Programmable Auto Ranging
• Range ID contacts (Quantity 4) Form A normally open contacts
• Two fully adjustable oxygen concentration alarm set points with programmable relay function Form C contacts
• Programmable auto cal capability with mode ID Form A normally open contacts
• Remotely operated calibration capability (Customer supplied valves and 24 VDC signal)
• Self diagnostics with Form C failure alarm contacts
• Full duplex RS-232 communication link for remote indication system status and control of cal/zero function
• Power 110/220 VAC, 50/60 Hz (specify at time of order)
• Explosion proof analysis unit. Enclosure is U/L and CSA listed for Class 1, Div 1, Groups B, C & D service NEMA 4/7 rated
• Sample flow indicator
• Stainless steel passages and fittings with nylon cell block
• Fast response Class B-1 Micro-fuel Cell (MFC) sensor
• Monitoring inert gas blanketing
• Air separation and liquefaction
• Chemical reaction monitoring
• Semiconductor manufacturing
• Petrochemical process control
• Quality assurance
• Gas analysis certification